C.M. Brown, L. Cristofolini, et al.
Chemistry of Materials
This paper presents the fabrication and characteristics of a magnetically actuated micromechanical scanner/stage with five degrees of freedom (X, Y, Z, and tilt about the X and Y axes) intended for use as a compact positioning device in parallel scanning probe applications. The entire scanner has a volume of 30×30×2 mm3. It shows a DC displacement amplitude to drive current ratio of 330 nm/mA along the X and Y axes, of 50 nm/mA along the Z axis, and has a resonant frequency in the X/Y plane of 61 Hz.
C.M. Brown, L. Cristofolini, et al.
Chemistry of Materials
R. Ghez, J.S. Lew
Journal of Crystal Growth
Sharee J. McNab, Richard J. Blaikie
Materials Research Society Symposium - Proceedings
D.D. Awschalom, J.-M. Halbout
Journal of Magnetism and Magnetic Materials